LPG Reducer fatigue point is a common failure of a reducer. Fatigue erosion starts to be smaller and lighter in diameter, and most of them occur in the place below the round and round. The machine cannot continue to use.
The cause of the fatigue point of the LPG Reducer Manufacturers is as follows:
1. Lubricating oil expires or deteriorated, the viscosity is too low or failure, so that the oil film cannot be formed between the gear surface. In this way, the teeth and teeth directly contact the tooth surface fatigue.
2. During the installation process, the reducer of the reducer is not strictly implemented by the maintenance process, resulting in poor installation, causing local contact with the tooth surface, and excessive load caused to cause fatigue and erosion of the tooth surface.
3. The use of super limits or bearings and bearings with bearing and bearing seat holes in the transmission of the decelerator is too large, causing the transmission bearing vibration to vibrate too much and cause the load to increase.
During the use of the reducer, due to the pushing of time may affect the equipment, some failures will gradually occur. When we use the reducer, we must pay attention to the usual maintenance lubrication work, pay attention to the period of use of lubricating oil, and pay attention to adding timely.
The cause of the fatigue point of LPG Reducer Factory is mainly the problem introduced above. Our machine fatigue erosion problems occur. We all need to solve these problems in time. The correct method operation uses us. Everyone needs to do it.